Answer: An average furnace repair costs $304, or between $131 and $478. Electric furnaces can run $300 or less to repair. Gas furnace repairs range from $375 to $1,200 due to complexity. Most HVAC repair professionals charge $75 per hour but can range from $50 to $150 per hour.
Related Articles About Furnace Repair

Easy And Also Safe Gas Heating System Repair Works That You Can Do
Many individuals take into consideration the furnace as one of their home’s most important devices, which is very much true most especially throughout cold weather when getting some warmth consumption is extremely crucial.
Additionally, this is the actual reason that knowing how to repair your heater in case some troubleshooting problems develop can be very important.
On And Off Problems
If your heater keeps switching on as well as off, this is usually simply easy trouble with the device’s heat anticipator. To start repairing, just situate your thermostat and also open it. When you open the package, you will see inside a little disk that is located in the middle. Take an excellent consideration the disc. You will seethat it has a variety of calibration notches.
Take a closer look as well as you will certainly find words “LONGER” on it. Then, search for a little deal with that touches awire. When you locate that little handle, turn ittowards words “LONGER”.
After completing the actions, activate your heater andlet it runs for a few hours. If it works okay, then you’re done. However, if the heating system is still turning on as well as off, simply duplicate the actions given above.
Proceed to do so until the issue quits.
Close down Issues
This trouble is additionally a simple one, which is comparable to the very first trouble. All you need to do is get rid of your unit’s thermostat cover, after that adhere to the claimed actions in the first issue. But, in this instance, what you have todo is transform the clockwise to “SHORTER”, instead of moving it toward “LONGER”. This ought to repair your problem. If it does not just duplicate the actions up until youget it working.
No Warm Generation If your unit is not generating heat, after that the issue is most probably the pilot light. Attempt to take a look at your pilot burner and see if it is switched on or if it is out. If you found it to beout, then you would need to relight it. In case you do not understand exactly how to relight it, simply consult your device’s manual or contact your maker. This is a relatively easy job that you can do by simply following some straightforward instructions.
No Air
If your unit is running, however, doesn’t blow any air, then here is just how you fix it. First, you should turn offthe power of your device. Also, you should shut off thegas from the gas valve which is offering your furnace.
After that, remove the door of your furnace cabinet so youcan have access to your blower.
When you currently have full gain access to, look into the number that is stamped on the belt of your heating system.
Then, go to your neighborhood store and also get an exact replacement of the belt.
When you’ve got the replacement belt, then go back to your heating system cabinet and mount the brand-new belt.
Generally, you can simply slide it on your motor’s smaller pulley block then placed it on your electric motor’s blower pulley. Attempt revolving the blower pulley-block using yourhand, while you hold the belt in place. Be careful from having your fingers caught though.
If you get this right, you must be able to get the belt right in place. If it looks a little also limited, then you may require to change the motor mount so therecan be more slack in the fixture. After adjusting, try to retighten the stress once again, when you have the belt in the right area.
It would be better to check your manufacturer’s specifications concerning the proper tension needed for your device. Usually, your belt ought to deflect atleast about an inch whenever you press it down.